KST Plus Logo
Начало
|
За КСТ Плюс
|
Изпрати страницата на E-mail  
English version English version  
American Polywater® Corporation
Лубриканти и почистващи течности
Лубриканти за изтегляне
Лубриканти за вдухване
Течности за почистване
Програма за пресмятане на параметрите
 Pull-Planner™ 2000
Ръководство за избор на лубриканти
Тренинг и видео

Програма за пресмятане на параметрите при изтегляне на оптичен кабел
Pull-Planner™ 2000 for Windows™

Pull-Planner™ 2000 for Windows™ calculates cable pulling tension and sidewall pressure around bends using the pulling equations. Tension estimates are useful in designing conduit systems and planning cable pulls. Such planning can save time and money by minimizing splices, vaults, pulling set-ups, etc., while ensuring installation tensions that won't damage cable.

Pull-Planner™ 2000 for Windows™ follows the proven approach of the earlier DOS version and approaches a pull in "segments." Each segment normally consists of a straight section followed by a bend. On-screen "HELP" menus throughout the program explain data entry and terminology. If you are familiar with cable and conduit terminology, very little training is required to run the program.

Pull-Planner™ 2000 for Windows™ comes on one CD. It will run on 16 or 32 bit Windows™ systems. Total installation will consume 4 to 7 megabytes of hard drive space.
 

Key Features for Faster and Easier Calculations

Windows™ version of the well-known Pull-Planner™ 2000.
Drop down menus and command button controls for intuitive operation.
Accepts pull and cable data saved under DOS version.
Large, easy to use customized cable data base (up to 50 cables).
Runs metric or English units.
Mouse point and click feature speeds calculations.
Clipboard feature allows transfer of data into word processing document.
Line document of conduit to check accuracy of data entry.
Standard Windows™ interfaces for printing, saving, and coloring screen.
Large friction coefficient data base.
Plus Much More!

Additional Features and Performance
Calculate and recalculate tensions and sidewall pressures automatically during easy changes of friction coefficient, incoming tension, or pull direction.
Establish a custom cable data file with your common cables by name, weight, and OD. Just click on these standards for quick data entry.
Print pull details and calculation results to Windows™ printer, or copy and paste data through the clipboard to other Windows™ programs.
Determine "maximum" allowable pulling tension and/or sidewall pressure and "flag" screen or printer output when maximum tension is surpassed.
Determine conduit fill, cable configuration, and jam ratio for any combination of wires and cables in a pull.
Add, subtract, change, or insert conduit segments in a pull for analysis. Change segment data by directly clicking on the data cell.
Save all details of a pull (cables and conduit design) to disk for future recall.
Change cable data without re-entering conduit system details. Allows quick recalculations in the same duct bank.
Calculate the quantity of Polywater® Lubricant needed for the pull.
Use built-in friction coefficient database that includes a broad range of common cable jackets, conduits, and pulling lubricants.
Use "dual" friction coefficients if desired, one at high and one at low sidewall bearing pressure, plus establish a sidewall pressure for the transition.
Back-calculate an effective friction coefficient from field measured tensions--useful for additional calculations in similar environments.
System Requirements
IBM PC or compatible.
Windows™ based program (runs on 16 or 32 bit systems).
CD drive.
Monitor (VGA for color options).
Printer is optional.
 

Important Notice: The statements and information here are made in good faith based on tests and observations we believe to be reliable. However, the completeness and accuracy of the information is not guaranteed. Before using, the end-user should conduct whatever evaluations are necessary to determine that the product is suitable for the intended use. The user assumes all risks and liability in connection with such use. The statements contained herein are made in lieu of all warranties, express or implied, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose, which warranties are hereby expressly disclaimed. American Polywater's only obligation shall be to replace such quantity of the product proven to be defective. Except for the replacement remedy, KST Plus Ltd. or American Polywater shall not be liable for any loss, injury or damage, direct or indirect, arising from the use or the failure to properly use these products, regardless of the legal theory asserted. The foregoing may not be altered except by a written agreement by the officers of American Polywater Corporation.

За повече информация, въпроси и коментари ни пишете на sales@kstplus.com
© 2007 КСТ Плюс ООД