Cable Pulling Lubricants |
Polywater® F for Fiber Optic Cable Pulling |
|
|
|
Specifications
| Parameter |
Value |
| Lubricity |
Low Shear (straight conduit sections): LDPE-jacketed cable on LDPE innerduct at 2.2 N/m (.15 lbs./ft.) (weight of cable) sidewall force, coefficient of static friction <.15.
High Shear (bent conduit sections): LDPE-jacketed cable on LDPE innerduct at 2.91 kN/m (200 lbs./ft.) sidewall force, coefficient of static friction <.12.
|
| Percent non-volatile solids |
4.5 to 5.5% |
| Appearance |
Transparent to slightly opaque, orange-colored, stringy liquid material |
| Wax, grease and silicone content |
none |
| Temperature use range |
-5°C to 50°C (20°F to 120°F) for Polywater® F; -30°C to 50°C (-20°F to 120°F) for Polywater® WF |
| pH |
8.0 to 9.5 |
| Cable compatibility |
No deleterious effects on physical or electrical properties of common* cable jackets. |
| Polyethylene stress cracking |
No stress cracking on LDPE cable jacket when tested by ASTM D1693. |
| Temperature stability |
No more than a 20% change in Brookfield viscosity from 5°C to 40°C (40°F to 100°F). No phase-out after five freeze/thaw cycles or 24-hour exposure at 50°C (120°F). |
| Toxicity |
Non-toxic and non-sensitizing. Industrial use only. |
| Flammability |
Lubricant has no flash point and dried residue is non-flammable. |
| Cleanup |
Complete cleanup possible with water |
|
| |
Package Size and Catalog Numbers |
| Package Size |
Lubricant |
Units/Case |
| F® |
WF® |
| 208L drum (55-gallon) |
F-Drum |
WF-Drum |
1 |
| 18.9L pail (5-gallon) |
F-640 |
WF-640 |
1 |
| 9.6L jug (2½-gallon) |
F-320 |
WF-320 |
2 |
| 3.8L jug (1-gallon) |
F-128 |
WF-128 |
4 |
| 0.95L squeeze bottle (1-qt) |
F-35 |
WF-35 |
12 |
|
 |
|
| |
| *Contact KST Plus Ltd. or American Polywater® for specific recommendations on LSZH or LSHF cable jacket types. |
| |
Important Notice: The statements and information here are made in good faith based on tests and observations we believe to be reliable.
However, the completeness and accuracy of the information is not guaranteed.
Before using, the end-user should conduct whatever evaluations are necessary to determine that the product is suitable for the intended use.
The user assumes all risks and liability in connection with such use.
The statements contained herein are made in lieu of all warranties, express or implied, including, but not limited to, implied warranties of merchantability and fitness
for a particular purpose, which warranties are hereby expressly disclaimed. American Polywater's only obligation shall be to replace such quantity of the product proven to be defective.
Except for the replacement remedy, KST Plus Ltd. or American Polywater shall not be liable for any loss, injury or damage, direct or indirect, arising from the use or the failure to
properly use these products, regardless of the legal theory asserted.
The foregoing may not be altered except by a written agreement by the officers of American Polywater Corporation.
|
|